44 6178-2203
S41 Bit mapped register (Read Only Register)
Bit Interval Default Description
0..1 0..3 3 Compression selection:
0-No compression (AT%C0)
1-MNP5 (AT%C1)
2-V.42bis (AT%C2)
3-MNP5 or V.42bis (AT%C3)
2 0..1 1 Automatic line quality and fall back/fall forward:
0-Line quality and fall back/fall forward disabled
(AT%E0)
1- Line quality and fall back/fall forward enabled
(AT%E1)
3 0..1 0 Modem-to-modem flow control:
0-No flow control (AT\G0)
1-Modem-to-modem flow control (AT\G1)
4 0..1 0 MNP block or character stream control:
0-Character stream (AT\L0)
1-Blockmode (AT\L1)
5..7 0..7 0 Reserved
S46 V.42bis Data compression control
136 No data compression
138 – V.42bis data compression
Default 138 {136,138}.
S48 V.42 Negotiation Control
0 Force LAPM connection
7 Enable negotiation
128 Force value as specified in S36
Default 7 {0,7,128}.
Please also refer to S36
S82 Break-control for LAPM connections (Not stored with &W)
3 Break is sent immediately. Data in the buffer is stored.
7 Break is sent immediately. Data in the buffer is destroyed.
128 Break is buffered
Default 128 {3,7,128}.
S86 Call failure indication (Read Only Register, not stored with &W)
This register contains an indication of what went wrong after a dialling error.
Default 0 {0..255}.
S91 PSTN Transmit level (Directly stored in NVRAM)
Default 13 Default value and interval is country dependant {0..30} (dBm)